Solar Thermal Systems /
KAT-B BASIC ENAMELLED ACCUMULATION TANK 800-5000
Features
Volume
800 lt-5000 lt
Domestic Hot Water Maximum Operating Temperature
95˚C
Domestic Hot Water Maximum Operating Pressure
10 bar
Inner Surface Coating
Tank inner surface is enameled (glass-lined) in accordance with DIN 4753-3 Standard.
Manufactured in accordance with 2014/68 EU Pressure Equipment Directive, TS EN 13445-3 and TS EN 12897 Standards.
Insulation and Equipments
51.13 Basic Enamelled Accumulation Tank | 800L-1000L | 1500L-2000L | 2500L-3000L | 4000L-5000L | |
Insulation | x | x | x | x | |
STD/80 mm | STD/80 mm | STD/80 mm | STD/80 mm | ||
OPS/80 mm | OPS/80 mm | OPS/80 mm | OPS/80 mm | ||
OPS/80 mm | OPS/80 mm | OPS/80 mm | |||
Coating | Blueshell- Recyclable polyethylene cover that provides heat-saving | x | x | x | x |
Vinleks- Artificial Leather | STD | STD | STD | STD | |
OPS | OPS | OPS | OPS | ||
Equipment | STD/Ø100 | STD/Ø100 | STD/Ø100 | STD/Ø100 | |
Sensor Tube | |||||
Cleaning & Control Flange | STD/Ø125 mm | STD/Ø125 mm | STD/Ø125 mm | STD/Ø125 mm | |
Electric Heater | OPS/2″ | OPS/2″ | OPS/2″ | OPS/2″ | |
Cathodic Protection | Magnesium Anode | STD | STD | STD | STD |
Electronic Anode | OPS | OPS | OPS | OPS | |
Carrier Element | Steel leg system mounted on a palette from 3 different locations | STD | STD-x | x | x |
Circle steel leg system that provides circular floor contact | x | x-STD | STD | STD |
STD: Abbreviation for spare parts and equipments which belong to the standard products.
OPS: Abbreviation for the optional spare parts and equipments for non-standard products.
Technical Data
Description | Code | Unit | 51.13.20 | 51.13.21 | 51.13.22 | 51.13.23 | 51.13.24 | 51.13.25 | 51.13.26 | 51.13.27 |
Capacity | V | lt | 800 | 1000 | 1500 | 2000 | 2500 | 3000 | 4000 | 5000 |
Insulation Type & Thickness | i | mm | SPU/80 | SPU/80 | SPU/80 | SPU/80 | SPU/80 | SPU/80 | SPU/80 | SPU/80 |
Diameter | ØD | mm | 910 | 1010 | 1120 | 1310 | 1460 | 1460 | 1660 | 1660 |
Heightc | H | mm | 2110 | 2070 | 2375 | 2280 | 2160 | 2580 | 2575 | 3230 |
Primary/Secondary Energy Inlet/Outlet Connections | N1 | inch | 1½” | 1½” | 1½” | 1½” | 2″ | 2″ | 3″ | 3″ |
Cleaning & Control Flange Diameter | N2 | inch | Ø125 | Ø125 | Ø125 | Ø125 | Ø125 | Ø125 | Ø125 | Ø125 |
Thermometer / Sensor Tube Connections | N3 | inch/mm | ½” | ½” | ½” | ½” | ½” | ½” | ||
Circulation Return Connection | N4 | inch | 1½” | 1½” | 2″ | 2″ | ||||
Electric Heater Connection | N5 | inch | 2″ | 2″ | 2″ | 2″ | 2″ | 2″ | 2″ | 2″ |
Magnesium Anode Connection | N6 | inch | ||||||||
Blind Connection | N7 | inch | 1¼” | 1¼” | 2″ | 2″ | 2″ | 2″ | 2″ | 2″ |
Gross Weight | G | kg | 190 | 205 | 272 | 363 | 503 | 564 | 760 | 895 |
Tilt Height | R | mm | 2300 | 2305 | 2625 | 2630 | 2610 | 2965 | 3065 | 3635 |
The table shown above is prepared based on spare parts and equipments which belong to standard products; all products have internal threaded connections.
KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications.
All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and
schemes are considered exemplary by third parties.